JIS F7403 is the bronze hull valve - the sea valve that sits directly on the shell plating or the sea chest and is the ship's first line of defence against flooding. Bronze is used because the body is permanently wet and cannot be painted once fitted.
Key information for selection. Send your drawing or nameplate photo for an exact match.
| Item | Value |
|---|---|
| Standard | JIS F7403-1996 |
| Type | Hull (sea) globe valve, bolted bonnet |
| Nominal size | DN15–DN65 |
| Pressure | 5K (0.5 MPa) |
| Body material | BC6 cast bronze body and bonnet |
| Connection | Flanged, both ends |
| Media | Sea water · fresh water · fuel oil |
| Inspection & certificates | CCS · LR · BV · ABS · DNV · ZC |
| Part | Material | Trademark |
|---|---|---|
| Body, bonnet | Cast bronze | BC6 (CAC406) |
| Disc | Cast bronze | BC6 |
| Stem | Brass / stainless steel | C3771 / SUS403 |
| Seat | Integral bronze | — |
A hull valve differs from an ordinary globe valve in how it is fixed: the body spigot passes through the shell or bolts onto a sea chest pad, so the flange and the body outline have to match the plating detail, not just the pipe. Always send the shell drawing.
The disc closes with the flow direction - sea pressure helps it seat - so the valve is installed with the pressure side under the disc. Bronze 5K covers the small suctions: generator cooling, sanitary sea water, fire pump priming.
A bronze body is not welded to a steel shell. It is bolted through a spigot with a gasket, or fitted to a steel sea chest pad. Send us the detail and we quote the matching body form.
Hull valves are a class-society item - the surveyor wants to see the material certificate and the pressure test of the actual valve. CCS, LR, BV, ABS, DNV and ZC can all be arranged.
Yes. CCS, LR, BV, ABS, DNV and ZC inspection can be arranged before dispatch, and the certificate is issued against the actual heat number of the casting. State the society and the surveyor's requirements on the enquiry so it is included in the quotation rather than added later.
Our production follows the Chinese national (GB/CB) standards and customer drawings. If the part you are replacing follows JIS, DIN, EN or an IMPA-coded pattern, send the drawing or the flange dimensions: where the bolt circle, bolt count and face-to-face match a GB/CB type, we supply that type. Where they do not, we say so before quoting rather than after.
Five things decide the price: the standard number or the drawing, the DN size, the body material, the quantity, and whether a classification society certificate is required. A photo of the nameplate or the old valve is usually enough for us to identify the rest. Delivery port and required date help, but they are not needed for the first reply.