JIS F7360 is the hull gate valve - the large sea valve mounted on the sea chest or the shell plating, used as the main sea water suction isolation on larger ships. Full-bore when open, so the pump sees the least possible loss.
Key information for selection. Send your drawing or nameplate photo for an exact match.
| Item | Value |
|---|---|
| Standard | JIS F7360-1996 |
| Type | Hull (sea chest) gate valve, bolted bonnet |
| Nominal size | DN50–DN400 |
| Pressure | 5K (0.5 MPa) |
| Body material | SCPH2 cast steel body, bronze-faced wedge |
| Connection | Flanged, both ends |
| Media | Sea water · fresh water · fuel oil |
| Inspection & certificates | CCS · LR · BV · ABS · DNV · ZC |
| Part | Material | Trademark |
|---|---|---|
| Body, bonnet | Cast steel | SCPH2 / WCB |
| Disc, seat | Stainless steel overlay | SCS2 / 2Cr13 |
| Stem | Stainless steel | SUS403 |
| Gasket | Spiral wound / non-asbestos | — |
On a main sea water line the valve is the biggest single restriction after the sea chest, so a gate pattern is used rather than a butterfly: no disc in the flow path, no seat protruding into the bore.
The body carries a machined spigot that passes through the shell or bolts to a sea chest pad, so it is quoted against the shell drawing. Class survey is normally required - the certificate is issued to the actual valve, not to the batch.
Gate where head loss matters and the line is short; butterfly where space and weight matter more. Both are accepted by the class societies, so it usually comes down to the pump margin.
Either a long rising stem up to a handwheel at floor level, or a deck stand with a reach rod. We supply the extension and the stand to suit the distance you give us.
Yes. CCS, LR, BV, ABS, DNV and ZC inspection can be arranged before dispatch, and the certificate is issued against the actual heat number of the casting. State the society and the surveyor's requirements on the enquiry so it is included in the quotation rather than added later.
Our production follows the Chinese national (GB/CB) standards and customer drawings. If the part you are replacing follows JIS, DIN, EN or an IMPA-coded pattern, send the drawing or the flange dimensions: where the bolt circle, bolt count and face-to-face match a GB/CB type, we supply that type. Where they do not, we say so before quoting rather than after.
Five things decide the price: the standard number or the drawing, the DN size, the body material, the quantity, and whether a classification society certificate is required. A photo of the nameplate or the old valve is usually enough for us to identify the rest. Delivery port and required date help, but they are not needed for the first reply.