JIS F7353 is the cast iron SDNR valve: the same combined stop-and-check duty as F7351 but in DN50 to DN400, which is where most sea water and cooling lines actually sit.
Key information for selection. Send your drawing or nameplate photo for an exact match.
| Item | Value |
|---|---|
| Standard | JIS F7353-1996 |
| Type | Screwdown check (SDNR), globe pattern |
| Nominal size | DN50–DN400 |
| Pressure | 5K (0.5 MPa) |
| Body material | FC200 grey cast iron body, bronze disc |
| Connection | Flanged, both ends |
| Media | Sea water · fresh water · fuel oil |
| Inspection & certificates | CCS · LR · BV · ABS · DNV · ZC |
| Part | Material | Trademark |
|---|---|---|
| Body, bonnet | Grey cast iron | FC200 |
| Disc | Cast iron with bronze face | FC200 / BC6 |
| Stem | Brass | C3771 |
| Gland packing | Non-asbestos / PTFE | — |
Above DN50 the bronze version stops making sense economically, so the body becomes FC200 with a bronze disc, bronze seat ring and brass stem. The stem passes through a packed gland so the valve can be wound shut even against a live line.
IMPA codes run 751101 to 751111 across DN50 to DN400. Note that some catalogues list 751110 as DN350 and 751111 as DN400 while others show DN335/DN380 - quote the DN you need and let us check the code rather than ordering on the code alone.
Flow must enter under the disc, so the arrow on the body points from the seat side towards the bonnet side. Fitted backwards it will not open at all - this is the most common installation fault on SDNR valves.
Only if you also want the manual shut-off. A swing check has a lower pressure drop; an SDNR costs you some head loss through the globe-shaped seat but gives you isolation for free.
Yes. CCS, LR, BV, ABS, DNV and ZC inspection can be arranged before dispatch, and the certificate is issued against the actual heat number of the casting. State the society and the surveyor's requirements on the enquiry so it is included in the quotation rather than added later.
Our production follows the Chinese national (GB/CB) standards and customer drawings. If the part you are replacing follows JIS, DIN, EN or an IMPA-coded pattern, send the drawing or the flange dimensions: where the bolt circle, bolt count and face-to-face match a GB/CB type, we supply that type. Where they do not, we say so before quoting rather than after.
Five things decide the price: the standard number or the drawing, the DN size, the body material, the quantity, and whether a classification society certificate is required. A photo of the nameplate or the old valve is usually enough for us to identify the rest. Delivery port and required date help, but they are not needed for the first reply.