GB/T1856 is the discharge chest: branches come in, one common outlet leaves, and the outlet carries a non-return element so the main cannot push back into the branches. It is the counterpart of the suction chests in GB/T1854/1855/2499.
Key information for selection. Send your drawing or nameplate photo for an exact match.
| Item | Value |
|---|---|
| Standard | GB/T1856 |
| Type | Single row, discharge pattern |
| Nominal size | DN15–DN50 branches |
| Pressure | 0.2 MPa |
| Body material | HT200 cast iron body, bronze trim |
| Connection | Flanged, both ends |
| Media | Bilge water · ballast water · fire main |
| Inspection & certificates | CCS · LR · BV · ABS · DNV · ZC |
| Part | Material | Trademark |
|---|---|---|
| Chest body | Cast iron | HT200 |
| Bonnet | Cast iron | HT200 |
| Disc | Cast iron with bronze facing | HT200 / ZCuSn10Zn2 |
| Stem | Tin brass | HSn62-1 |
| Gasket | Rubber bonded fibre | — |
Suction and discharge chests are not interchangeable — one collects from several branches into one outlet, the other distributes. Fitting a suction chest on a discharge is a common specification error and leaves the branches unprotected against back pressure.
The non-return element sits on the common outlet rather than on each branch, so one check protects the whole chest. Bonnets are individually removable and the discs are bronze faced.
Follow the flow: several branches into one pipe is a suction chest, one pipe into several branches is a discharge chest. The standard numbers are different and so are the castings.
Yes, the plain pattern is available; but if the outlet can see pressure from the main — a fire main with a stand-by pump, for instance — keep it.
Yes. CCS, LR, BV, ABS, DNV and ZC inspection can be arranged before dispatch, and the certificate is issued against the actual heat number of the casting. State the society and the surveyor's requirements on the enquiry so it is included in the quotation rather than added later.
Our production follows the Chinese national (GB/CB) standards and customer drawings. If the part you are replacing follows JIS, DIN, EN or an IMPA-coded pattern, send the drawing or the flange dimensions: where the bolt circle, bolt count and face-to-face match a GB/CB type, we supply that type. Where they do not, we say so before quoting rather than after.
Five things decide the price: the standard number or the drawing, the DN size, the body material, the quantity, and whether a classification society certificate is required. A photo of the nameplate or the old valve is usually enough for us to identify the rest. Delivery port and required date help, but they are not needed for the first reply.