GB/T1854-93 R/RS is a single-row, two-valve cast iron globe chest: two shut-off valves on one flanged body so a suction or discharge manifold can be built without a fabricated header. RS adds the drain connection.
Key information for selection. Send your drawing or nameplate photo for an exact match.
| Item | Value |
|---|---|
| Standard | GB/T1854-93 |
| Type | R · RS (with drain) |
| Nominal size | DN15–DN50 branches |
| Pressure | 0.2 MPa |
| Body material | HT200 cast iron body, bronze trim |
| Connection | Flanged, both ends |
| Media | Bilge water · ballast water · sea water |
| Inspection & certificates | CCS · LR · BV · ABS · DNV · ZC |
| Part | Material | Trademark |
|---|---|---|
| Chest body | Cast iron | HT200 |
| Bonnet | Cast iron | HT200 |
| Disc | Cast iron with bronze facing | HT200 / ZCuSn10Zn2 |
| Stem | Tin brass | HSn62-1 |
| Gasket | Rubber bonded fibre | — |
Valve chests exist because a fabricated manifold in a bilge or ballast system is a weld map of leak paths. A single casting has one set of flanges to the ship's piping and one gasket face per bonnet — fewer joints, and a shorter assembly.
R is the plain chest; RS carries a drain or bleed tapping so the section can be emptied before the bonnets are opened. Each valve has its own rising-stem handwheel and can be worked independently.
RS has a drain/bleed tapping on the chest so the body can be emptied before maintenance. On a bilge manifold that is normally worth the small extra cost.
Yes — the same body family covers globe, globe-check and check arrangements; tell us the combination and the standard number (1854/1855/2499) and we build to it.
Yes. CCS, LR, BV, ABS, DNV and ZC inspection can be arranged before dispatch, and the certificate is issued against the actual heat number of the casting. State the society and the surveyor's requirements on the enquiry so it is included in the quotation rather than added later.
Our production follows the Chinese national (GB/CB) standards and customer drawings. If the part you are replacing follows JIS, DIN, EN or an IMPA-coded pattern, send the drawing or the flange dimensions: where the bolt circle, bolt count and face-to-face match a GB/CB type, we supply that type. Where they do not, we say so before quoting rather than after.
Five things decide the price: the standard number or the drawing, the DN size, the body material, the quantity, and whether a classification society certificate is required. A photo of the nameplate or the old valve is usually enough for us to identify the rest. Delivery port and required date help, but they are not needed for the first reply.