A storm valve is the last line of defence for a deck drain. If it fails closed, the " engine room floods. That is why the test sequence matters more than the sales sheet.
The assembled body is filled and pressurised with water at 1.5 times the design pressure, " held for the time required by the applicable standard, and inspected for leakage at every " joint, seam and casting repair. No weeping, no misting, no drop in gauge pressure.
With the disc closed, pressure is applied to each side in turn. The acceptance criterion " depends on the seat material and the standard you are working to — metal seats and " rubber seats are not judged the same way, and a metal-seated valve that passes a soft-seat " acceptance figure is not necessarily a better valve.
Face-to-face, flange drilling, and the marking — size, pressure class, material, " heat number, flow arrow. A valve that passes pressure but carries the wrong heat number is " still a rejected valve, because the traceability chain is broken.
Each unit leaves with a hydrostatic test record and a material certificate for the " pressure-bearing parts. If the vessel is classed, those documents are what the surveyor " asks for first.
Ask us for a sample test record with your enquiry and we will send a redacted copy so " you can see the format before you place an order.